36kV Composite Sheath Metal Oxide Surge Arrester for Outdoor Power Protection

Factory: We are a professional manufacturer providing OEM custom production services.

4.8/5 Customer Rating | Views: 0
Brand WishPower
Product Category Surge Arrester
Model SAW-36kV
Price 83
Source Factory Yes
Color Grey/Red
Country / Region China
Lead Time 15?0 Working Days

Product Overview

Wishpower 36kV composite sheath metal oxide surge arrester is designed for 36kV AC power systems. It protects transformers, switchgear, cable terminals, overhead lines and substation equipment from lightning overvoltage and switching overvoltage.

Compared with traditional porcelain housed arresters, the composite sheath design offers better safety, easier handling and improved adaptability for outdoor power networks.

Main advantages include:

  1. High-performance zinc oxide varistors with excellent nonlinear characteristics and low residual voltage.

  2. Silicone rubber composite housing with good hydrophobicity, pollution resistance and anti-aging performance.

  3. Lightweight polymer housing, reducing transportation and installation risks.

  4. Suitable for outdoor environments such as humid areas, polluted areas, coastal regions and high UV exposure locations.

  5. Compact structure with reliable sealing performance for long-term operation.

  6. Available with different installation accessories for pole-mounted, substation and equipment protection applications.

Core Features

  1. Reliable Overvoltage Protection
    The zinc oxide varistor works as the core protection element. It remains highly resistive under normal operating voltage and quickly conducts surge current during overvoltage events.

  2. Durable Composite Sheath
    The silicone rubber housing provides excellent hydrophobicity and pollution flashover resistance, making the arrester suitable for long-term outdoor use.

  3. Low Residual Voltage
    The arrester effectively limits lightning and switching overvoltage, reducing insulation stress on protected equipment.

  4. Lightweight Design
    Compared with porcelain housed arresters, the composite sheath arrester is lighter and easier to transport, handle and install.

  5. Excellent Sealing Performance
    The sealed structure prevents moisture and contaminants from entering the internal components.

  6. Wide Application Range
    It can be used for distribution lines, overhead lines, substations, transformers, cable terminals and outdoor switchgear.

  7. Low Maintenance Cost
    The stable structure and weather-resistant materials help reduce routine maintenance requirements.

Product Structure

A 36kV composite sheath metal oxide surge arrester is generally composed of the following parts:

  1. Zinc Oxide Varistor Blocks
    The core protection components that discharge surge current and limit residual voltage.

  2. Silicone Rubber Composite Housing
    Provides external insulation, weather resistance, pollution resistance, UV resistance and hydrophobic performance.

  3. Fiberglass Reinforced Support Structure
    Provides mechanical support and structural strength for outdoor operation.

  4. Metal End Fittings
    Used for electrical connection and mechanical installation, usually with corrosion-resistant treatment.

  5. Sealing System
    Prevents moisture, water and contaminants from entering the internal structure.

  6. Optional Disconnector or Surge Counter
    Disconnectors, surge counters or monitoring devices can be supplied according to project requirements.


Technical Specifications

ParameterApplication Range
Product Name36kV Composite Sheath Metal Oxide Surge Arrester
Product TypeHigh Voltage, Outdoor, Polymer Housed, Zinc Oxide Surge Arrester
Applicable SystemAC medium and high voltage distribution system
Rated Voltage36kV class
Nominal Discharge CurrentCommonly 5kA or 10kA, configurable by project requirement
Housing MaterialHTV silicone rubber composite housing
Core ElementZinc oxide nonlinear varistor blocks
Installation MethodPole-mounted, line-mounted, substation-mounted, equipment terminal installation
Operating EnvironmentOutdoor, humid area, polluted area, coastal area, high UV environment
Protected EquipmentTransformer, overhead line, cable terminal, switchgear, substation equipment
Frequency50Hz / 60Hz
Operating TemperatureCustomizable according to project environment
External Insulation PerformancePollution resistant, aging resistant, excellent hydrophobicity
Mechanical PerformanceImpact resistant, vibration resistant, lightweight
Reference StandardIEC 60099-4 or related power industry standards


Product Structure

Main Applications

Wishpower 36kV composite sheath metal oxide surge arrester is widely used in the following industries and applications:

  1. Distribution Line Protection
    Used in 36kV distribution systems to limit lightning overvoltage impact on line equipment.

  2. Overhead Line Protection
    Installed at key points of overhead lines to reduce lightning trip-outs and equipment damage.

  3. Substation Equipment Protection
    Used for incoming and outgoing feeders, busbars and switchgear protection in substations.

  4. Pole-Mounted Systems
    Suitable for outdoor poles, distribution poles, line branches and tower-mounted installations.

  5. Outdoor Distribution Networks
    Applied in urban distribution networks, rural networks and industrial power distribution systems.

  6. Transformer Protection
    Installed on the high-voltage side of transformers to protect windings and insulation systems.

  7. Cable Protection
    Used at cable terminals, compact substations and cable entrance or exit points.

  8. Renewable Energy Systems
    Suitable for wind farms, solar power plants and energy storage step-up systems.


Testing Capability

Wishpower performs strict factory inspection and performance verification for 36kV composite sheath metal oxide surge arresters to ensure long-term outdoor operation reliability.

Main testing capabilities include:

  1. DC Reference Voltage Test
    Verifies the electrical performance and volt-ampere stability of zinc oxide varistors.

  2. Leakage Current Test
    Checks insulation condition and internal quality under operating voltage.

  3. Residual Voltage Test
    Verifies voltage limiting capability under impulse current conditions.

  4. Power Frequency Withstand Voltage Test
    Confirms the insulation level of the external housing and internal structure.

  5. Partial Discharge Test
    Helps identify internal insulation defects and improves operational reliability.

  6. Sealing Performance Test
    Ensures stable operation in humid, rainy and polluted outdoor environments.

  7. Mechanical Strength Test
    Checks the mechanical reliability of end fittings, structure and mounting components.

  8. Appearance and Dimension Inspection
    Inspects shed profile, housing surface, fitting dimensions and assembly quality.


Packaging & Transportation

To keep products safe during transportation and storage, we use the following packaging methods:

  • Individual Packaging: Each product is wrapped with protective film, packed in a high-strength carton, and cushioned with buffer materials.
  • Pallet Packaging: Multiple products are fixed on wooden pallets and wrapped with stretch film, suitable for container shipping.
  • Export Packaging: Fumigated wooden cases, moisture-proof treatment, and detailed packing lists are provided according to sea freight requirements.

Customization Service

WishPower can provide the following customization options according to customer requirements:

  • Structural Dimensions: Adjust overall height, creepage distance, shed quantity, and shed diameter.
  • End Fittings: Customize ball-socket, tongue-clevis, eye, or other interface types according to connection requirements.
  • Color: Standard gray, with red, yellow, blue, and other colors available subject to MOQ.
  • Special Environments: Formulations for extreme cold (-60 C), strong UV exposure, heavy pollution, and other harsh conditions.
  • Voltage Classes: Full-range customization from 10kV to 1000kV.
  • Marking: Customer logos or model numbers can be molded or printed on the product.

For specific customization requirements, please contact our sales engineers. We will provide a technical solution within 24 hours.

FAQ

Q: What information should I provide for a quotation?

A: Please provide voltage level, product type, quantity, application environment, standard, drawings or technical specifications if available.

Q: Are composite insulators suitable for coastal areas?

A: Yes. Composite insulators with silicone rubber housing provide good hydrophobicity and anti-pollution performance, making them suitable for coastal and polluted environments.

Q: How do I choose the right composite insulator for my project?

A: You can provide voltage level, installation type, mechanical load, creepage distance and operating environment. Our team will recommend the suitable model.

Q: Can you provide customized insulation products?

A: Yes. WishPower supports customized voltage ratings, creepage distances, fittings, colors and drawings according to project requirements.

Q: Can you supply complete products for transmission and distribution projects?

A: Yes. We can provide composite insulators, surge arresters, fuse cutouts, insulating bushings and related power insulation products.