Product Overview
RIP dry type reactor bushing is a key insulating and current-carrying component used in high voltage reactor equipment. It provides reliable electrical insulation between the energized conductor and grounded equipment structure. Wishpower RIP dry type reactor bushing is designed with resin impregnated paper insulation, offering stable electrical performance, low partial discharge, strong mechanical strength and an oil-free structure for modern power systems.
Wishpower RIP dry type reactor bushing uses a resin impregnated paper condenser core as the main insulation system. The insulation paper is wound, impregnated with epoxy resin and cured to form a compact dry-type insulating body. Compared with traditional oil-filled bushings, this design eliminates oil leakage risks and improves safety, environmental performance and maintenance convenience.
Key advantages of Wishpower bushings include:
Resin impregnated paper insulation with stable dielectric performance;
Oil-free dry type structure with reduced maintenance requirements;
Optional composite silicone rubber housing for outdoor applications;
Suitable for reactors, substations and high voltage equipment;
Custom design for different voltage levels, current ratings and installation dimensions;
Manufactured according to IEC standards and project specifications.
Core Features
RIP Condenser Core Design
The resin impregnated paper condenser core helps optimize electric field distribution and improves insulation reliability.Oil-Free Structure
The dry type design avoids oil leakage, reduces fire risk and supports cleaner operation.Low Partial Discharge
Controlled winding, vacuum impregnation and curing processes help reduce internal voids and improve long-term stability.High Mechanical Strength
The compact structure is suitable for reactor operation conditions, including vibration, mechanical load and installation stress.Excellent Weather Resistance
Composite silicone rubber housing provides hydrophobicity, UV resistance and anti-aging performance for outdoor service.Flexible Customization
Wishpower can customize voltage rating, current rating, flange size, conductor type, creepage distance and installation interface.
Product Structure
A RIP dry type reactor bushing generally consists of:
Current-carrying conductor: transfers rated current through the bushing;
RIP condenser core: provides main insulation and electric field grading;
Composite outer housing: improves outdoor insulation and pollution performance;
Mounting flange: connects the bushing to reactor tank or equipment interface;
Terminal fittings: connect to busbar, cable or equipment terminals;
Sealing components: protect the internal insulation from moisture and contamination;
Test tap or measuring terminal: supports dielectric loss, capacitance or condition monitoring.
Technical Specifications
| Parameter | Application Range |
|---|---|
| Product Type | RIP dry type reactor bushing |
| Applicable Equipment | Reactor, substation equipment, capacitor system, high voltage apparatus |
| Rated Voltage | 24kV, 35kV, 66kV, 110kV, 220kV and customized ratings |
| Rated Current | Customized according to project requirements |
| Insulation Structure | Resin impregnated paper condenser core, dry type oil-free design |
| Outer Insulation Material | Composite silicone rubber or customized material |
| Installation Method | Flange mounting, vertical mounting, horizontal mounting or special angle mounting |
| Service Environment | Indoor, outdoor, polluted area, substation and industrial power system |
| Creepage Distance | Customized according to voltage level, pollution class and customer standard |
| Applicable Standards | IEC 60137, IEC 61462, IEC 62217 or project specifications |
| Test Items | Power frequency withstand, lightning impulse, partial discharge, dielectric loss, sealing test |
| Customization | Voltage, current, flange size, conductor design and shed profile can be customized |
Product Structure
Main Applications
Wishpower RIP dry type reactor bushing is suitable for:
Shunt reactors;
Series reactors;
Current-limiting reactors;
Filter reactors;
High voltage substations;
Capacitor compensation systems;
High voltage switchgear equipment;
Transmission and distribution systems;
Industrial power systems;
Renewable energy substations and grid connection systems.
Testing Capability
Wishpower performs strict routine and type-related tests to ensure reliable performance of RIP dry type reactor bushings.
Power frequency withstand voltage test;
Lightning impulse withstand voltage test;
Partial discharge test;
Dielectric dissipation factor measurement;
Capacitance measurement;
Sealing performance test;
Visual and dimensional inspection;
Mechanical strength inspection;
Creepage distance and shed profile inspection;
Special tests according to customer project requirements.
Packaging & Transportation
To keep products safe during transportation and storage, we use the following packaging methods:
- Individual Packaging: Each product is wrapped with protective film, packed in a high-strength carton, and cushioned with buffer materials.
- Pallet Packaging: Multiple products are fixed on wooden pallets and wrapped with stretch film, suitable for container shipping.
- Export Packaging: Fumigated wooden cases, moisture-proof treatment, and detailed packing lists are provided according to sea freight requirements.
Customization Service
Wishpower can provide the following customization options according to customer requirements:
- Structural Dimensions: Adjust overall height, creepage distance, shed quantity, and shed diameter.
- End Fittings: Customize ball-socket, tongue-clevis, eye, or other interface types according to connection requirements.
- Color: Standard gray, with red, yellow, blue, and other colors available subject to MOQ.
- Special Environments: Formulations for extreme cold (-60 C), strong UV exposure, heavy pollution, and other harsh conditions.
- Voltage Classes: Full-range customization from 10kV to 1000kV.
- Marking: Customer logos or model numbers can be molded or printed on the product.
For specific customization requirements, please contact our sales engineers. We will provide a technical solution within 24 hours.
Downloads
FAQ
A: Please provide voltage level, product type, quantity, application environment, standard, drawings or technical specifications if available.
A: You can provide voltage level, installation type, mechanical load, creepage distance and operating environment. Our team will recommend the suitable model.
A: Yes. Composite insulators with silicone rubber housing provide good hydrophobicity and anti-pollution performance, making them suitable for coastal and polluted environments.
A: Yes. WishPower supports customized voltage ratings, creepage distances, fittings, colors and drawings according to project requirements.
A: Our products can be designed and tested according to IEC, ANSI, GB and customer-specific technical requirements.