33kV-38kV Drop Out Fuse for Outdoor High Voltage Distribution Protection

唯实: 我们是一家专业的制造商,提供OEM定制生产服务。

4.8/5 Customer Rating | 阅读量: 4
品牌 WishPower
产品类别 熔断器
产品型号 DOF-33kV
产品价格 38
源头工厂
颜色 红色/灰色
国家 / 地区 中国
交货周期 15-30个工作日

产品详情

Wishpower 33kV-38kV drop out fuse is developed for outdoor distribution networks with voltage classes such as 33kV, 35kV, 36kV and 38kV. When overload or short-circuit current occurs, the fuse link melts and interrupts the fault current. After operation, the fuse tube drops down to provide a visible open point for line inspection and maintenance.

Key advantages include:

  1. Suitable for outdoor high voltage distribution systems
    It can be used for overhead lines, pole-mounted transformers, branch feeders, cable transitions and outdoor distribution equipment.

  2. Reliable insulation performance
    Polymer housing and porcelain housing options are available to meet different insulation, anti-pollution and weather-resistant requirements.

  3. Visible fault isolation
    After fuse operation, the fuse tube drops down and forms a clear disconnection point, making inspection easier.

  4. Easy installation and maintenance
    The compact structure supports pole-mounted installation and convenient fuse tube replacement.

  5. Strong environmental adaptability
    It is suitable for high temperature, humidity, pollution, coastal, sandy and long-term outdoor operating conditions.

Core Features

  1. Reliable overload and short-circuit protection
    The fuse operates when abnormal current occurs, helping prevent fault expansion in distribution networks.

  2. Visible open-point indication
    The drop-out tube provides a clear visual indication after operation, improving maintenance safety and efficiency.

  3. Excellent outdoor weather resistance
    The insulation structure offers good resistance to ultraviolet radiation, aging, moisture and pollution flashover.

  4. Compact structure and flexible installation
    It is suitable for poles, crossarms, distribution transformer stations and outdoor line branches.

  5. Optional load break function
    Standard protection type and load break type can be selected according to project requirements.

  6. Compatible with different fuse link ratings
    Fuse links can be selected based on transformer capacity, feeder load and protection coordination requirements.

Product Structure

The 33kV-38kV drop out fuse usually consists of the following components:

  1. Insulation support
    Polymer composite insulation or porcelain insulation provides the main insulating and mechanical support.

  2. Upper contact assembly
    It ensures stable contact with the upper end of the fuse tube and supports release during fuse operation.

  3. Lower contact assembly
    It supports the lower end of the fuse tube and maintains stable electrical and mechanical connection.

  4. Fuse tube assembly
    The fuse tube contains the fuse link and drops down after fault interruption.

  5. Fuse link
    Different rated current options are selected according to line protection requirements.

  6. Mounting bracket
    It is used for installation on poles, crossarms or outdoor distribution structures.

  7. Terminal connectors
    They connect incoming and outgoing conductors with reliable electrical conductivity and mechanical strength.


技术参数

ParameterApplication Range
Product Name33kV-38kV Drop Out Fuse
Applicable Voltage33kV, 35kV, 36kV, 38kV distribution systems
Product TypeDrop out, expulsion, high voltage, outdoor, load break type optional
Insulation HousingPolymer housing or porcelain housing available
Installation MethodOutdoor pole mounting, crossarm mounting, distribution line installation
Applicable SystemThree-phase AC distribution system, overhead distribution network
Protected EquipmentDistribution transformer, overhead line, branch feeder, cable transition
Rated CurrentSelected according to project requirements
Breaking CapacitySelected according to grid short-circuit current level
Operating EnvironmentOutdoor, high humidity, polluted, coastal, sandy and high temperature areas
Operation MethodAutomatic drop-out after fuse link operation, operated with insulated stick
Maintenance MethodFuse tube replacement, contact inspection, insulator cleaning, terminal tightening


产品结构

主要应用领域

The 33kV-38kV drop out fuse is widely used in the following industries and applications:

  • Distribution line protection: used for overload and short-circuit protection in medium and high voltage distribution lines.

  • Overhead line sectional protection: installed at branch points to isolate faulty sections.

  • Transformer protection: used on the high voltage side of pole-mounted distribution transformers.

  • Outdoor distribution systems: suitable for rural networks, urban peripheral distribution and industrial power supply systems.

  • Pole-mounted projects: suitable for installation on poles, crossarms and outdoor line structures.

  • Cable protection: used at cable transition points between overhead lines and underground cables.

  • Substation outgoing feeders: applicable to external feeders, branch lines and auxiliary distribution circuits.

  • Renewable energy projects: suitable for wind farms, solar power plants and outdoor step-up distribution lines.


测试能力

Wishpower can carry out relevant inspections and tests for 33kV-38kV drop out fuse according to project requirements to ensure reliable outdoor high voltage operation.

  1. Power frequency withstand voltage test
    Verifies insulation capability under rated voltage and overvoltage conditions.

  2. Lightning impulse withstand voltage test
    Checks insulation reliability under lightning impulse conditions.

  3. Partial discharge test
    Detects abnormal discharge risks inside the insulation structure.

  4. Mechanical strength test
    Verifies the stability of brackets, contacts, fuse tubes and insulation supports.

  5. Temperature rise test
    Checks the temperature rise performance of conductive parts under rated current.

  6. Interrupting performance test
    Verifies fuse operation and drop-out reliability under fault current conditions.

  7. Pollution and weather resistance test
    Evaluates performance under humidity, pollution, ultraviolet exposure and outdoor aging conditions.

  8. Appearance and dimension inspection
    Checks product appearance, creepage distance, installation dimensions and assembly quality.


包装与运输

为确保产品在运输和储存过程中的安全,我们采用以下包装方法:

  • 独立包装: 每件产品均用保护膜包裹,装入高强度纸箱,并用缓冲材料进行缓冲。
  • 托盘包装: 多个产品固定在木托盘上,并用拉伸膜包裹,适合集装箱运输。
  • 出口包装: 根据海运要求提供熏蒸木箱、防潮处理和详细的装箱单。

定制服务

WishPower可根据客户需求提供以下定制选项:

  • 结构尺寸: 调整总高度、爬升高度、棚架数量和棚架直径。
  • 端部配件: 根据连接要求定制球窝、舌形接头、环眼或其他接口类型。
  • 颜色: 标准灰色,红色、黄色、蓝色等其他颜色可根据最低起订量提供。
  • 特殊环境: 适用于极寒(-60°C)、强紫外线照射、严重污染和其他恶劣条件的配方。
  • 电压等级: 10kV 至 1000kV 全范围定制。
  • 标记: 客户的标志或型号可以模压或印刷在产品上。

如有任何定制需求,请联系我们的销售工程师。我们将在24小时内提供技术解决方案。

FAQ

Q: How do I choose the right composite insulator for my project?

A: You can provide voltage level, installation type, mechanical load, creepage distance and operating environment. Our team will recommend the suitable model.

Q: Can you supply complete products for transmission and distribution projects?

A: Yes. We can provide composite insulators, surge arresters, fuse cutouts, insulating bushings and related power insulation products.

Q: What information should I provide for a quotation?

A: Please provide voltage level, product type, quantity, application environment, standard, drawings or technical specifications if available.

Q: What standards can your products meet?

A: Our products can be designed and tested according to IEC, ANSI, GB and customer-specific technical requirements.

Q: Can you provide customized insulation products?

A: Yes. WishPower supports customized voltage ratings, creepage distances, fittings, colors and drawings according to project requirements.